Difference between revisions of "16mm Transfer Station"

From Help Wiki
Line 15: Line 15:
 
# In '''StCamSWare''' go to '''Option''' > '''Settings''' and a new window will open.
 
# In '''StCamSWare''' go to '''Option''' > '''Settings''' and a new window will open.
 
# Click the '''Advanced''' button in the bottom right.  If the  bottom right button is "Simple" than you are already in the '''Advanced''' window.
 
# Click the '''Advanced''' button in the bottom right.  If the  bottom right button is "Simple" than you are already in the '''Advanced''' window.
 +
# Go to the '''Trigger''' tab and configure the following settings.
 +
#* Operation Mode : Trigger
 +
#* Trigger Source : Hardware
 +
#* Trigger Mode : Edge Preset
 +
# Go to the '''IO''' tab and configure the following settings.
 +
#* I00 : Trigger Input [10]
 +
#* Polarity : Negative
 +
#* Trigger Mode : Edge Preset
  
 
[[Category:Multimedia Lab]]
 
[[Category:Multimedia Lab]]

Revision as of 16:10, 7 February 2014

Getting Ready

Power

  1. Turn on power strip
  2. Start the computer
  3. Turn on the projector (Back right)
  4. Log into computer

Cleaning

  1. Open StCamSWare from the desktop
  2. Turn projector to Still to turn on the light.
  3. Look at StCamSWare and if the image is dirty you need to clean the projector.
  4. Pull the light away from the projector and clean with canned air.

Settings

  1. In StCamSWare go to Option > Settings and a new window will open.
  2. Click the Advanced button in the bottom right. If the bottom right button is "Simple" than you are already in the Advanced window.
  3. Go to the Trigger tab and configure the following settings.
    • Operation Mode : Trigger
    • Trigger Source : Hardware
    • Trigger Mode : Edge Preset
  4. Go to the IO tab and configure the following settings.
    • I00 : Trigger Input [10]
    • Polarity : Negative
    • Trigger Mode : Edge Preset