(7 intermediate revisions by 3 users not shown) |
Line 1: |
Line 1: |
| + | Audio is a subjective field. Use your ears and good judgement to find out which mics you like for the different applications. The only thing that is not subjective is the fact that both ribbon and condenser microphones are more delicate and sensitive than dynamics, and thus easier to damage if treated carelessly or used to mic kick drums. |
| {| class="wikitable" style="text-align: center; background: Lavender;" | | {| class="wikitable" style="text-align: center; background: Lavender;" |
| |- | | |- |
Line 8: |
Line 9: |
| |D | | |D |
| |||XLR | | |||XLR |
− | || | + | ||30HZ-15KHZ |
| |- | | |- |
| |MAB | | |MAB |
Line 18: |
Line 19: |
| |D | | |D |
| |||XLR | | |||XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MAE | | |MAE |
Line 28: |
Line 29: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MAF | | |MAF |
Line 37: |
Line 38: |
| |D | | |D |
| |||XLR | | |||XLR |
− | | | + | |20HZ-17KHZ |
| |- | | |- |
| |MAH | | |MAH |
Line 49: |
Line 50: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MAN | | |MAN |
Line 61: |
Line 62: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MAV | | |MAV |
Line 75: |
Line 76: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MBN | | |MBN |
Line 87: |
Line 88: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |40HZ-16KHZ |
| |- | | |- |
| |MBO | | |MBO |
Line 99: |
Line 100: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MPB | | |MPB |
Line 111: |
Line 112: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |40HZ-16KHZ |
| |- | | |- |
| |MBQ | | |MBQ |
Line 127: |
Line 128: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |40HZ-16KHZ |
| |- | | |- |
| |MCK | | |MCK |
Line 141: |
Line 142: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MCNT | | |MCNT |
Line 152: |
Line 153: |
| |C | | |C |
| | | | | |
− |
| |
| 9V BAT | | 9V BAT |
| | | |
| ONLY | | ONLY |
| |XLR OR 1/8" | | |XLR OR 1/8" |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MCP | | |MCP |
Line 171: |
Line 171: |
| |48V OR 2X9V BAT | | |48V OR 2X9V BAT |
| |XLR | | |XLR |
− | | | + | |50HZ-15KHZ |
| + | |
| + | VARIES |
| |- | | |- |
| |MCS | | |MCS |
Line 185: |
Line 187: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MED | | |MED |
Line 200: |
Line 202: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |80HZ-13KHZ |
| |- | | |- |
| |MEG | | |MEG |
Line 211: |
Line 213: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |80HZ-15KHZ |
| |- | | |- |
| |MEJ | | |MEJ |
Line 221: |
Line 223: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |80HZ-15KHZ |
| |- | | |- |
| |MEM | | |MEM |
Line 231: |
Line 233: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-20KHZ |
| |- | | |- |
| |MEO | | |MEO |
Line 241: |
Line 243: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |40HZ-18KHZ |
| |- | | |- |
| |MEP | | |MEP |
Line 251: |
Line 253: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |45HZ-18KHZ |
| |- | | |- |
| |MER | | |MER |
Line 260: |
Line 262: |
| |D | | |D |
| |||XLR | | |||XLR |
− | | | + | |80HZ-15KHZ |
| |- | | |- |
| |MES | | |MES |
Line 270: |
Line 272: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-19KHZ |
| |- | | |- |
| |MET | | |MET |
Line 280: |
Line 282: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |45HZ-18KHZ |
| |- | | |- |
| |MEW | | |MEW |
Line 294: |
Line 296: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |10HZ-20KHZ |
| |- | | |- |
| |MFH | | |MFH |
Line 306: |
Line 308: |
| |NO | | |NO |
| |XLR | | |XLR |
− | | | + | |60HZ-8KHZ |
| |- | | |- |
| |MHA | | |MHA |
Line 317: |
Line 319: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |50HZ-18KHZ |
| |- | | |- |
| |MHB | | |MHB |
Line 333: |
Line 335: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MHD | | |MHD |
Line 343: |
Line 345: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |70HZ-16KHZ |
| |- | | |- |
| |MHE | | |MHE |
Line 353: |
Line 355: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-15KHZ |
| |- | | |- |
| |MHF | | |MHF |
Line 363: |
Line 365: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MHG | | |MHG |
Line 375: |
Line 377: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |40HZ-20KHZ |
| |- | | |- |
| |MHK | | |MHK |
Line 385: |
Line 387: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MHM | | |MHM |
Line 395: |
Line 397: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MHS | | |MHS |
Line 405: |
Line 407: |
| | | | | |
| |XLR | | |XLR |
| + | |50HZ-20KHZ |
| + | |- |
| + | |MEF |
| + | |[[File:BETA52A.JPG|frameless|155x155px]] |
| + | |SHURE BETA 52A |
| + | |SUPERCARDIOID |
| + | |Supercardioid specifically for kick drums |
| + | |D |
| | | | | |
| + | |XLR |
| + | |20HZ- |
| + | 10KHZ |
| |- | | |- |
| |MML | | |MML |
Line 417: |
Line 430: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-23KHZ |
| |- | | |- |
| |MNA | | |MNA |
Line 427: |
Line 440: |
| | | | | |
| |XLR | | |XLR |
| + | |30HZ-17KHZ |
| + | |- |
| + | |MKH |
| + | |[[File:MKH40.jpg|centre|frameless|152x152px]] |
| + | |SENNHEISER MKH 40 |
| + | |CARDIOID |
| + | |The MKH 40 P 48 is a high frequency condenser microphone with an excellent frequency range. |
| + | |C |
| + | |48V |
| + | |XLR |
| + | |40HZ- |
| + | 20KHZ |
| + | |- |
| + | |MAD |
| + | |[[File:E605.JPG|frameless|160x160px]] |
| + | |SENNHEISER |
| + | E604 DRUM MIC KIT |
| + | |CARDIOID |
| + | |Mic kit specifically built for snare drums. Emphasis on mid and high frequencies, with a fairly clear low frequency clarity. Based on MD 421 technology. |
| + | |D |
| | | | | |
| + | |XLR |
| + | |40HZ- |
| + | 18KHZ |
| |- | | |- |
| |MNC | | |MNC |
Line 441: |
Line 477: |
| |MND | | |MND |
| |[[File:Mnd.png|frameless]] | | |[[File:Mnd.png|frameless]] |
− | |SENHEISER 441 | + | |SENNHEISER 441 |
| |SUPERCARDIOID | | |SUPERCARDIOID |
| |Vocal and instrument mic equipped with a 5 position bass roll off switch and a treble boost switch | | |Vocal and instrument mic equipped with a 5 position bass roll off switch and a treble boost switch |
Line 447: |
Line 483: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-20KHZ |
| |- | | |- |
| |MNE | | |MNE |
Line 458: |
Line 494: |
| |9V ONLY | | |9V ONLY |
| |XLR | | |XLR |
− | | | + | |40HZ-20KHZ |
| |- | | |- |
| |MOF | | |MOF |
Line 472: |
Line 508: |
| BAT | | BAT |
| |XLR | | |XLR |
− | | | + | |40HZ-14KHZ |
| |- | | |- |
| |MOH | | |MOH |
Line 484: |
Line 520: |
| 48V | | 48V |
| |XLR | | |XLR |
− | | | + | |40HZ-15KHZ |
| |- | | |- |
| |MPP | | |MPP |
Line 494: |
Line 530: |
| |48V | | |48V |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MRB | | |MRB |
Line 504: |
Line 540: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-18KHZ |
| |- | | |- |
| |MRC | | |MRC |
Line 514: |
Line 550: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |30HZ-15KHZ |
| |- | | |- |
| |MRR | | |MRR |
Line 524: |
Line 560: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MRY | | |MRY |
Line 534: |
Line 570: |
| | | | | |
| |XLR | | |XLR |
− | | | + | |40HZ-18KHZ |
| |- | | |- |
| |MTS | | |MTS |
Line 545: |
Line 581: |
| |EXT | | |EXT |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MTS2 | | |MTS2 |
Line 555: |
Line 591: |
| |EXT | | |EXT |
| |XLR | | |XLR |
− | | | + | |20HZ-20KHZ |
| |- | | |- |
| |MSV | | |MSV |
Audio is a subjective field. Use your ears and good judgement to find out which mics you like for the different applications. The only thing that is not subjective is the fact that both ribbon and condenser microphones are more delicate and sensitive than dynamics, and thus easier to damage if treated carelessly or used to mic kick drums.
TESC SKU |
Image |
Brand/Model |
Pattern |
Usage |
Dynamic / Condenser |
Battery Type |
Connection |
More details
|
MAA |
|
AKG D202E
|
CARDIOID
|
Designed to eliminate proximity effect, very flat frequency response.
|
D
|
|
XLR
|
30HZ-15KHZ
|
MAB
|
|
AKG D224E
|
CARDIOID
|
Designed to handle high SPL, good midrange,
-20db rear attenuation at all freqs
|
D
|
|
XLR
|
20HZ-20KHZ
|
MAE
|
|
AKG 460B
|
CARDIOID
|
Low self-noise. Equipped with low cut filters or 10db pad.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MAF
|
|
AKG D112
|
CARDIOID
|
Used primarily on kick drums. Handles high SPL.
|
D
|
|
XLR
|
20HZ-17KHZ
|
MAH
|
|
AKG C414
|
VARIOUS
|
Large diaphragm condenser.
Used on instruments
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MAN
|
|
ASTON
ORIGIN
|
CARDIOID
|
Large diaphragm condenser. Used on instruments and vocals
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MAV
|
|
AUDIO
TECHNICA
4060
|
CARDIOID
|
Vacuum tube condenser. Used on vocals, instruments and amps.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MBN
|
|
NEUMANN
KM-84
|
CARDIOID
|
Small diaphragm FET condenser. Used for drum overheads and on hi-hats
|
C
|
48V
|
XLR
|
40HZ-16KHZ
|
MBO
|
|
NEUMANN
U87
|
VARIOUS
|
Used for vocals. has low cut, 10db pad, and omni, cardioid, and figure 8 pickup switches
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MPB
|
|
NEUMANN
KM-83
|
OMIN
|
The Omnidirectional equivalent of the km-84.
|
C
|
48V
|
XLR
|
40HZ-16KHZ
|
MBQ
|
|
NEUMANN
U47
(FET)
|
HYPER
CARDIOID
|
Large diaphragm FET condenser. Good for studio vocals.
|
C
|
48V
|
XLR
|
40HZ-16KHZ
|
MCK
|
|
AVANTONE
CK-40
|
STEREO
VARIOUS
|
Stereo condenser with adjustable pickup patterns and swiveling capsule. Good for recording a room or in a figure 8 pattern.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MCNT
|
|
RODE NT4
|
STEREO
CARDIOID
|
Used for stereo recording of live performances, ensembles, etc
|
C
|
9V BAT
ONLY
|
XLR OR 1/8"
|
20HZ-20KHZ
|
MCP
|
|
CROWN
PZM
|
HEMI-
SPHERICAL
|
Used for recording multiple voices in a conference or meeting setting.
|
PZM
|
48V OR 2X9V BAT
|
XLR
|
50HZ-15KHZ
VARIES
|
MCS
|
|
STUDIO
PROJECTS
C4
|
CARDIOID AND OMNI CAPSULES
|
Small diaphragm condenser. Used for overhead or stereo recording of instruments or ensembles.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MED
|
|
ELECTRO
VOICE (EV)
635A
|
OMNI
|
A live interview microphone designed to eliminate plosives and other proximity effects.
|
D
|
|
XLR
|
80HZ-13KHZ
|
MEG
|
|
EV RE-16
|
SUPERCARDIOID
|
Excellent for podium use where high intelligibility is important.
|
D
|
|
XLR
|
80HZ-15KHZ
|
MEJ
|
|
EV RE-15
|
SUPERCARDIOID
|
Used for broadcasting and instrument recordings. Also used to mic speaker cabinets.
|
D
|
|
XLR
|
80HZ-15KHZ
|
MEM
|
|
EV RE-55
|
OMNI
|
Handheld vocal use for interviews or recording of orchestras etc.
|
D
|
|
XLR
|
40HZ-20KHZ
|
MEO
|
|
EV CS-15
|
CARDIOID, OMNI CAPSULES
|
Increased bass response at close proximities. Handheld vocal use.
|
C
|
48V
|
XLR
|
40HZ-18KHZ
|
MEP
|
|
EV RE-20
|
CARDIOID
|
Very popular vocal recording mic, used extensively in broadcasting.
|
D
|
|
XLR
|
45HZ-18KHZ
|
MER
|
|
EV RE-18
|
SUPERCARDIOID
|
Designed to reduce microphone handling noise. Used for spoken word/announcing.
|
D
|
|
XLR
|
80HZ-15KHZ
|
MES
|
|
EV 408B
|
SUPERCARDIOID
|
Instrument mic, used mostly on instruments with high SPL, drums, horns, etc.
|
D
|
|
XLR
|
40HZ-19KHZ
|
MET
|
|
EV 308B
|
CARDIOID
|
Slightly less directional version of the 408b. Instrument mic.
|
D
|
|
XLR
|
45HZ-18KHZ
|
MEW
|
|
EARTH
WORKS
TC 20
|
OMNI
|
Reference flat microphone, 150db SPL rating, used for calibration or for very loud instruments/sound effects
|
C
|
48V
|
XLR
|
10HZ-20KHZ
|
MFH
|
|
CASCADE
FATHEAD
|
FIGURE 8
|
Used for mid-side pickup, and on instruments and vocals.
|
RIBBON
|
NO
|
XLR
|
60HZ-8KHZ
|
MHA
|
|
SHURE SM58
|
CARDIOID
|
Suitable for vocal use in live performance, sound reinforcement, and studio recording.
|
D
|
|
XLR
|
50HZ-18KHZ
|
MHB
|
|
SHURE
BETA
87A
|
SUPERCARDIOD
|
Hand held vocal mic
good feedback rejection
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MHD
|
|
SHURE SM53
|
CARDIOID
|
Vintage hand held vocal mic, designed for low proximity effect.
|
D
|
|
XLR
|
70HZ-16KHZ
|
MHE
|
|
SHURE SM57
|
CARDIOID
|
good for live sound reinforcement, instruments and vocals. bright, clean sound.
|
D
|
|
XLR
|
40HZ-15KHZ
|
MHF
|
|
SHURE SM81
|
CARDIOID
|
Used on instruments, popular for pianos.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MHG
|
|
SHURE VP88
|
CARDIOID,
FIGURE 8
|
Stereo recording mic used in broadcasting.
|
C
|
48V
|
XLR
|
40HZ-20KHZ
|
MHK
|
|
SHURE KSM32
|
CARDIOID
|
General purpose condenser mic, useable for vocals/instruments etc. equipped with -15db and low cut switches.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MHM
|
|
SHURE KSM137
|
CARDIOID
|
Small diaphragm condenser designed for instruments.
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MHS
|
|
SHURE SM7B
|
CARDIOID
|
Shure’s response to the EV RE-20, a popular broadcasting vocal mic.
|
D
|
|
XLR
|
50HZ-20KHZ
|
MEF
|
|
SHURE BETA 52A
|
SUPERCARDIOID
|
Supercardioid specifically for kick drums
|
D
|
|
XLR
|
20HZ-
10KHZ
|
MML
|
|
MARSHAL
MXL2003
|
CARDIOID
|
General purpose condenser mic, useable on vocals, instruments, ensembles etc
|
C
|
48V
|
XLR
|
20HZ-23KHZ
|
MNA
|
|
SENNHEISER 421
|
CARDIOID
|
Vocal or instrument mic popular in studios
|
D
|
|
XLR
|
30HZ-17KHZ
|
MKH
|
|
SENNHEISER MKH 40
|
CARDIOID
|
The MKH 40 P 48 is a high frequency condenser microphone with an excellent frequency range.
|
C
|
48V
|
XLR
|
40HZ-
20KHZ
|
MAD
|
|
SENNHEISER
E604 DRUM MIC KIT
|
CARDIOID
|
Mic kit specifically built for snare drums. Emphasis on mid and high frequencies, with a fairly clear low frequency clarity. Based on MD 421 technology.
|
D
|
|
XLR
|
40HZ-
18KHZ
|
MNC
|
|
MNC CONDENSER COMBO KIT
|
VARIOUS
|
Useful for field recording, comes with various pickup patterns for versatility of recording.
|
C
|
48V OR AA
|
XLR
|
|
MND
|
|
SENNHEISER 441
|
SUPERCARDIOID
|
Vocal and instrument mic equipped with a 5 position bass roll off switch and a treble boost switch
|
D
|
|
XLR
|
40HZ-20KHZ
|
MNE
|
|
DR.NORMAR'S BINAURAL HEAD
(MKE 2002)
|
OMNI
|
Sennheiser binaural microphone pair, for recording a 3d stereo field for playback over headphones.
|
C
|
9V ONLY
|
XLR
|
40HZ-20KHZ
|
MOF
|
|
SONY ECM50
|
OMNI
|
Vintage lavalier vocal mic
|
C
|
48V
OR E90
BAT
|
XLR
|
40HZ-14KHZ
|
MOH
|
|
SONY ECM22P
|
CARDIOID
|
Instrument/vocal mic, can use external phantom power or battery power between 3.7 and 9 volts
|
C
|
206 BAT OR
48V
|
XLR
|
40HZ-15KHZ
|
MPP
|
|
PACIFIC PRO LD1
|
CARDIOID
|
Large diaphragm condenser, used for vocals, instruments, ensembles etc
|
C
|
48V
|
XLR
|
20HZ-20KHZ
|
MRB
|
|
BEYER M160
|
HYPERCARDIOID
|
Designed for instruments, popular on strings.
|
RIBBON
|
|
XLR
|
40HZ-18KHZ
|
MRC
|
|
COLES 4038
|
FIGURE 8
|
Vocal/instrument mic, popular with BBC broadcasting and recording studios.
|
RIBBON
|
|
XLR
|
30HZ-15KHZ
|
MRR
|
|
RCA 77DX
|
VARIOUS
|
Vintage ribbon mic, featuring cardioid, omni, and figure 8 polar patterns. Popular in broadcasting for vocals.
|
RIBBON
|
|
XLR
|
20HZ-20KHZ
|
MRY
|
|
ROYER R121
|
FIGURE 8
|
High quality ribbon instrument mic.
|
RIBBON
|
|
XLR
|
40HZ-18KHZ
|
MTS
|
|
CHAMELEON LABS TS-1
|
OMNI,
CARDIOID
|
Small diaphragm tube mic, used primarily on instruments
|
C
|
EXT
|
XLR
|
20HZ-20KHZ
|
MTS2
|
|
CHAMELEON LABS TS-2
|
VARIOUS
|
Large diaphragm tube condenser, used primarily on vocals.
|
C
|
EXT
|
XLR
|
20HZ-20KHZ
|
MSV
|
|
SE ELECTRONICS SE 5000
|
|
Large diaphragm tube condenser, used on vocals
|
C
|
EXT
|
XLR
|
|
MSZ
|
|
SE ELECTRONICS SE 5600
|
|
Large diaphragm tube condenser, used on vocals
|
C
|
EXT
|
XLR
|
|