Difference between revisions of "IC-IC25A-2 Information Table"
From Help Wiki
(Created page with '<!-- IC-IC25A-2 Information Schema Template --> {| class="wikitable" |+ '''Schema Information''' ! Schema List !! Schema Value |- | align="Left" | ''Instrument_CommonName'' | ali…') |
(location change) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | <!-- IC-IC25A-2 Information | + | <!-- IC-IC25A-2 Information Table --> |
{| class="wikitable" | {| class="wikitable" | ||
− | |+ ''' | + | |+ '''Information Table''' |
− | ! | + | ! Table List !! Table Value |
|- | |- | ||
| align="Left" | ''Instrument_CommonName'' | | align="Left" | ''Instrument_CommonName'' | ||
Line 14: | Line 14: | ||
|- | |- | ||
| align="Left" | ''Instrument_Manufacturer'' | | align="Left" | ''Instrument_Manufacturer'' | ||
− | | align="right" | Dionex | + | | align="right" | [http://www.dionex.com Dionex] |
|- | |- | ||
| align="Left" | ''Instrument_Model'' | | align="Left" | ''Instrument_Model'' | ||
− | | align="right" | IC25A | + | | align="right" | [http://www.dionex.com/en-us/documents/manuals/ic-rfic/lp-72182.html IC25A] |
|- | |- | ||
| align="Left" | ''Instrument_Serial#'' | | align="Left" | ''Instrument_Serial#'' | ||
Line 32: | Line 32: | ||
|- | |- | ||
| align="Left" | ''Instrument_Building'' | | align="Left" | ''Instrument_Building'' | ||
− | | align="right" | [https://trello.com/ | + | | align="right" | [https://trello.com/b/oIs5OMYX/tesc-scientific-instrumentation-location-lab-i Lab I ] |
|- | |- | ||
| align="Left" | ''Instrument_Floor'' | | align="Left" | ''Instrument_Floor'' | ||
− | | align="right" | | + | | align="right" | 2 |
|- | |- | ||
| align="Left" | ''Instrument_Room'' | | align="Left" | ''Instrument_Room'' | ||
− | | align="right" | | + | | align="right" | 2037 |
|- | |- | ||
− | | align="Left" | '' | + | | align="Left" | ''Instrument_Acquisition_Date'' |
| align="right" | ? | | align="right" | ? | ||
|- | |- | ||
Line 65: | Line 65: | ||
|- | |- | ||
| align="Left" | ''Computer_OS_Version'' | | align="Left" | ''Computer_OS_Version'' | ||
− | | align="right" | XP Professional 5.1.2600 | + | | align="right" | XP Professional {5.1.2600} |
|- | |- | ||
| align="Left" | ''Computer_RAM'' | | align="Left" | ''Computer_RAM'' | ||
Line 81: | Line 81: | ||
| align="Left" | ''Software_Product_Version'' | | align="Left" | ''Software_Product_Version'' | ||
| align="right" | 6.80 SP2 Build 2284 | | align="right" | 6.80 SP2 Build 2284 | ||
+ | |- | ||
+ | | align="Left" | ''Software_Product_LicenseKey'' | ||
+ | | align="right" | QJQARB-EQSRLR-7CFQYI-F9FV7F | ||
|- | |- | ||
| align="Left" | ''Software_Last_Updated'' | | align="Left" | ''Software_Last_Updated'' | ||
| align="right" | ? | | align="right" | ? | ||
|} | |} | ||
− | </br> | + | <br/> |
+ | <br/> | ||
---- | ---- | ||
− | [[Scientific Instrumentation | | + | [[IC-IC25A-2 | back to '''Instrument''' page]] |
+ | <br/> | ||
+ | [[Scientific Instrumentation | back to '''Main''' page]] | ||
+ | <br/> | ||
[[Category:SISchema]] | [[Category:SISchema]] | ||
<!-- END --> | <!-- END --> |
Latest revision as of 13:56, 13 November 2013
Table List | Table Value |
---|---|
Instrument_CommonName | IC-IC25A-2 |
Instrument_Name | Ion Chromatography System |
Instrument_Picture | |
Instrument_Manufacturer | Dionex |
Instrument_Model | IC25A |
Instrument_Serial# | 01060377 |
Instrument_Asset_Tag | 041993 |
Instrument_TurnKeySolution | No |
Instrument_Roaming | No |
Instrument_Building | Lab I |
Instrument_Floor | 2 |
Instrument_Room | 2037 |
Instrument_Acquisition_Date | ? |
Computer_Hostname | SC-IC2 |
Computer_IP | DHCP |
Computer_MAC | 00-03-47-D4-DC-48 |
Computer_Make | Gateway |
Computer_Model | E-3600 |
Computer_Asset_Tag | 050841 |
Computer_OS | Windows |
Computer_OS_Version | XP Professional {5.1.2600} |
Computer_RAM | 1 GB |
Computer_HD | 30 GB |
Software_Vendor | Dionex |
Software_Product_Name | Chromeleon |
Software_Product_Version | 6.80 SP2 Build 2284 |
Software_Product_LicenseKey | QJQARB-EQSRLR-7CFQYI-F9FV7F |
Software_Last_Updated | ? |