Difference between revisions of "GC-MSD-2"
From Help Wiki
(One intermediate revision by the same user not shown) | |||
Line 15: | Line 15: | ||
<br/> | <br/> | ||
---- | ---- | ||
− | + | ===== Notes ===== | |
+ | {| class="wikitable" | ||
+ | |+ '''Agilent Technical Support''' | ||
+ | ! Contact !! Telephone Number | ||
+ | |- | ||
+ | | align="Left" | Call Center | ||
+ | | align="Right" | 1-800-227-9770 | ||
+ | |- | ||
+ | | align="Left" | Brian Phillips, Field Service Engineer | ||
+ | | align="Right" | 425-356-6310 | ||
+ | |} | ||
+ | <br/> | ||
+ | <br/> | ||
+ | {| class="wikitable" | ||
+ | |+ '''Private Network Configuration''' | ||
+ | ! <u>'''Host'''</u> !! <u>'''IP'''</u> | ||
+ | |- | ||
+ | | align="Left" | Computer | ||
+ | | align="Right" | 10.1.1.100 | ||
+ | |- | ||
+ | | align="Left" | GC | ||
+ | | align="Right" | 10.1.1.101 | ||
+ | |- | ||
+ | | align="Left" | MSD | ||
+ | | align="Right" | 10.1.1.102 | ||
+ | |} | ||
+ | <br/> | ||
+ | <br/> | ||
+ | Pump | ||
* [[File:GC-MSD-2 pump.jpg | 50px | pump]] | * [[File:GC-MSD-2 pump.jpg | 50px | pump]] | ||
+ | <br/> | ||
+ | <br/> | ||
+ | ====== Installation ====== | ||
+ | * When MSD ChemStation is installed, a shortcut in the Windows start menu may not have been created to the utility program that configures communication to the GC instrument. The configuration tool is called msconfig.net.exe, and will be locatd in this default path: C:\msdchem\MSexe\msconfig.net.exe | ||
+ | ** When Agilent MSD Configuration (msconfig.net.exe) is configured, it will create a shortcut on the desktop to launch MSD ChemStation --MSTop.exe to be specific-- for communication with configured instrument --the shortcut will correspond to the instrument number {1-4}. | ||
+ | <br/> | ||
+ | <br/> | ||
+ | [[File:Agilent MSD ChemStation msconfig.net.exe Utility.png]] | ||
<br/> | <br/> | ||
<br/> | <br/> |
Latest revision as of 08:00, 19 April 2013
Gas Chromatograph Wikipedia entry
Mass Selective Detector Wikipedia entry
Manuals
Information Table
Notes
Contact | Telephone Number |
---|---|
Call Center | 1-800-227-9770 |
Brian Phillips, Field Service Engineer | 425-356-6310 |
Host | IP |
---|---|
Computer | 10.1.1.100 |
GC | 10.1.1.101 |
MSD | 10.1.1.102 |
Pump
Installation
- When MSD ChemStation is installed, a shortcut in the Windows start menu may not have been created to the utility program that configures communication to the GC instrument. The configuration tool is called msconfig.net.exe, and will be locatd in this default path: C:\msdchem\MSexe\msconfig.net.exe
- When Agilent MSD Configuration (msconfig.net.exe) is configured, it will create a shortcut on the desktop to launch MSD ChemStation --MSTop.exe to be specific-- for communication with configured instrument --the shortcut will correspond to the instrument number {1-4}.